FACTS TO CONSIDER ABOUT THE LOCATION
Carefully choose an indoor location for the new water heater, because
the placement is a very important consideration for the safety of the
occupants in the building and for the most economical use of the
appliance. This water heater is not for use in manufactured
(mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater in a
new location, the following critical points must be observed:
1. Select a location indoors as close as practical to the gas vent or
chimney to which the water heater vent is going to be connected,
and as centralized with the water piping system as possible.
2. Selected location must provide adequate clearances for servicing
and proper operation of the water heater.
Installation of the water heater must be accomplished in such a manner
that if the tank or any connections should leak, the flow will not cause
damage to the structure. For this reason, it is not advisable to install the
water heater in an attic or upper floor. When such locations cannot be
avoided, a suitable drain pan should be installed under the water heater.
Drain pans are available at your local hardware store. Such a drain
pan must have a minimum length and width of at least 2” (51 mm)
greater than the water heater dimensions and must be piped to an
adequate drain. The pan must not restrict combustion air flow.
Water heater life depends upon water quality, water pressure and the
environment in which the water heater is installed. Water heaters are
sometimes installed in locations where leakage may result in property
damage, even with the use of a drain pan piped to a drain. However,
unanticipated damage can be reduced or prevented by a leak detector
or water shut-off device used in conjunction with a piped drain pan.
These devices are available from some plumbing supply wholesalers
and retailers, and detect and react to leakage in various ways:
Sensors mounted in the drain pan that trigger an alarm or turn off
the incoming water to the water heater when leakage is detected.
Sensors mounted in the drain pan that turn off the water supply to
the entire home when water is detected in the drain pan.
Water supply shut-off devices that activate based on the water
pressure differential between the cold water and hot water pipes
connected to the water heater.
Devices that will turn off the gas supply to a gas water heater while
at the same time shutting off its water supply.
LL
LL
L
OCAOCA
OCAOCA
OCA
TING THE NEW WTING THE NEW W
TING THE NEW WTING THE NEW W
TING THE NEW W
AA
AA
A
TER HEATER HEA
TER HEATER HEA
TER HEA
TERTER
TERTER
TER
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES,
STORAGE AND UTILITY AREAS, ETC.): Flammable liquids (such as
gasoline, solvents, propane [LP or butane, etc.] and other substances
such as adhesives, etc.) emit flammable vapors which can be ignited
by a gas water heater’s pilot light or main burner. The resulting flashback
and fire can cause death or serious burns to anyone in the area, as
well as property damage. If installation in such areas is your only
option, then the installation must be accomplished in a way that the pilot
flame and main burner flame are elevated from the floor at least 18
inches. While this may reduce the chances of flammable vapors, from
a floor spill being ignited, gasoline and other flammable substances
should never be stored or used in the same room or area containing a
gas water heater or other open flame or spark producing appliance.
NOTE: Flammable vapors may be drawn by air currents from other
areas of the structure to the appliance.
Also, the water heater must be located and/or protected so it is not
subject to physical damage by a moving vehicle.
This water heater must not be installed directly on carpeting. Carpeting
must be protected by metal or wood panel beneath the appliance
extending beyond the full width and depth of the appliance by at least
3” (76.2 mm) in any direction, or if the appliance is installed in an alcove
or closet, the entire floor must be covered by the panel. Failure to heed
this warning may result in a fire hazard.