Periodic Maintenance
Temperature-Pressure Relief
Valve Operation
The temperature-pressure relief valve must be manually
operated at least once a year.
TEMPERATURE-PRESSURE
RELIEF VALVE
DISCHARGE PIPE
Failure to install and maintain a new properly listed tem-
perature-pressure relief valve will release the manufactur-
er from any claim which might result from excessive tem-
perature or pressure.
Draining
The water heater should be drained if being shut down
during freezing temperatures. Also periodic draining and
cleaning of sediment from the tank may be necessary.
1. Before beginning turn “OFF” the electric power supply
to the water heater.
2. CLOSE the cold water inlet valve to the water heater.
3. OPEN a nearby hot water faucet and leave open to
allow for draining.
4. Connect a hose to the drain valve and terminate to an
adequate drain or outdoors.
5. OPEN the water heater drain valve to allow for tank
draining.
NOTE: If the water heater is going to be shut down
and drained for an extended period, the drain valve
should be left open with hose connected allowing
water to terminate to an adequate drain.
6. Close the drain valve.
7. Follow “Filling the Water Heater” instructions in the
“Installing the New Water Heater” section.
8. Turn “ON” power to the water heater.
14
WARNING
HAZARD OF ELECTRICAL SHOCK! Before removing any
access panels or servicing the water heater, make sure the
electrical supply to the water heater is turned “OFF”.
Failure to do this could result in DEATH, SERIOUS BODI-
LY INJURY, OR PROPERTY DAMAGE.
WARNING
If the temperature-pressure relief valve on the appliance
weeps or discharges periodically, this may be due to ther-
mal expansion. The water heater may have a check valve
installed in the water line or a water meter with a check
valve. Consult a local plumbing contractor and/or the
local water utility for further information. Do not plug the
temperature-pressure relief valve.
WARNING
The temperature-pressure relief valve must be manually
operated at least once a year. Caution should be taken to
ensure that (1) no one is in front of or around the outlet of
the temperature-pressure relief valve discharge line, and
(2) the water manually discharged will not cause any
property damage or bodily injury. The water may be
extremely hot.
If after manually operating the valve, it fails to completely
reset and continues to release water, immediately close
the cold water inlet to the water heater, follow the drain-
ing instructions, and replace the temperature-pressure
relief valve with a new one.